| Property | Value | Unit | Source |
|---|---|---|---|
| ω | 0.2430 | KDB | |
| AP | 316.950 | K | KDB |
| ΔcH°liquid | -5222.60 ± 1.50 | kJ/mol | NIST |
| μ | 0.00 | debye | KDB |
| ΔfG° | 39.27 | kJ/mol | KDB |
| Δc,grossH | 5222.59 | kJ/mol | KDB |
| Δc,netH | 4870.511 | kJ/mol | KDB |
| ΔfH°gas | [-172.60; -171.80] | kJ/mol |
|
| ΔfH°gas | -171.90 | kJ/mol | KDB |
| ΔfH°gas | -172.60 | kJ/mol | NIST |
| ΔfH°gas | -171.80 ± 1.50 | kJ/mol | NIST |
| ΔfH°liquid | [-213.00; -212.20] | kJ/mol |
|
| ΔfH°liquid | -213.00 | kJ/mol | NIST |
| ΔfH°liquid | -212.20 ± 1.50 | kJ/mol | NIST |
| ΔfusH° | 8.31 | kJ/mol | Joback Calculated Property |
| ΔvapH° | [39.20; 40.60] | kJ/mol |
|
| ΔvapH° | 40.60 | kJ/mol | NIST |
| ΔvapH° | Outlier 39.20 ± 0.40 | kJ/mol | NIST |
| ΔvapH° | 40.00 ± 0.40 | kJ/mol | NIST |
| ΔvapH° | 40.00 ± 0.40 | kJ/mol | NIST |
| ΔvapH° | 40.40 | kJ/mol | NIST |
| ΔvapH° | 40.50 | kJ/mol | NIST |
| ΔvapH° | 40.50 ± 0.10 | kJ/mol | NIST |
| ΔvapH° | 40.47 | kJ/mol | NIST |
| ΔvapH° | 40.40 | kJ/mol | NIST |
| IE | [9.54; 9.67] | eV |
|
| IE | 9.54 | eV | NIST |
| IE | 9.67 ± 0.02 | eV | NIST |
| log10WS | [-4.25; -4.25] |
|
|
| log10WS | -4.25 | Aq. Solubility Prediction | |
| log10WS | -4.25 | Estimated Solubility | |
| logPoct/wat | 2.977 | Crippen Calculated Property | |
| McVol | 112.720 | ml/mol | McGowan Calculated Property |
| NFPA Fire | 3 | KDB | |
| NFPA Health | 1 | KDB | |
| Pc | [3000.00; 3250.00] | kPa |
|
| Pc | 3250.00 | kPa | Critical Point Measurements for Five n-Alkylcyclohexanes (C6 to C10) by the Pulse-Heating Method |
| Pc | 3000.00 | kPa | KDB |
| Inp | [818.00; 867.90] |
|
|
| Inp | 846.00 | NIST | |
| Inp | 851.00 | NIST | |
| Inp | 829.00 | NIST | |
| Inp | 842.20 | NIST | |
| Inp | Outlier 859.70 | NIST | |
| Inp | Outlier 867.90 | NIST | |
| Inp | 828.00 | NIST | |
| Inp | 833.60 | NIST | |
| Inp | 839.00 | NIST | |
| Inp | 843.00 | NIST | |
| Inp | 834.30 | NIST | |
| Inp | 842.80 | NIST | |
| Inp | 831.30 | NIST | |
| Inp | 831.70 | NIST | |
| Inp | 853.00 | NIST | |
| Inp | 837.00 | NIST | |
| Inp | 838.00 | NIST | |
| Inp | 848.00 | NIST | |
| Inp | 842.00 | NIST | |
| Inp | 842.00 | NIST | |
| Inp | 834.00 | NIST | |
| Inp | 840.00 | NIST | |
| Inp | 850.00 | NIST | |
| Inp | 840.00 | NIST | |
| Inp | 832.00 | NIST | |
| Inp | 836.00 | NIST | |
| Inp | 838.00 | NIST | |
| Inp | 841.00 | NIST | |
| Inp | 844.00 | NIST | |
| Inp | 834.30 | NIST | |
| Inp | 832.00 | NIST | |
| Inp | Outlier 856.00 | NIST | |
| Inp | 842.00 | NIST | |
| Inp | 825.00 | NIST | |
| Inp | 828.00 | NIST | |
| Inp | 834.00 | NIST | |
| Inp | 839.00 | NIST | |
| Inp | 845.00 | NIST | |
| Inp | 839.00 | NIST | |
| Inp | 839.00 | NIST | |
| Inp | 839.00 | NIST | |
| Inp | 839.00 | NIST | |
| Inp | 842.00 | NIST | |
| Inp | 835.92 | NIST | |
| Inp | 824.00 | NIST | |
| Inp | 843.00 | NIST | |
| Inp | 845.00 | NIST | |
| Inp | Outlier 854.00 | NIST | |
| Inp | 840.00 | NIST | |
| Inp | 832.00 | NIST | |
| Inp | 841.00 | NIST | |
| Inp | 832.20 | NIST | |
| Inp | 829.10 | NIST | |
| Inp | 828.40 | NIST | |
| Inp | 826.90 | NIST | |
| Inp | 829.10 | NIST | |
| Inp | 830.90 | NIST | |
| Inp | 838.10 | NIST | |
| Inp | 830.10 | NIST | |
| Inp | Outlier 818.00 | NIST | |
| Inp | 826.90 | NIST | |
| Inp | 829.10 | NIST | |
| Inp | 830.90 | NIST | |
| Inp | 829.10 | NIST | |
| Inp | 828.40 | NIST | |
| Inp | 827.00 | NIST | |
| Inp | 821.60 | NIST | |
| Inp | 824.96 | NIST | |
| Inp | 827.15 | NIST | |
| Inp | 827.11 | NIST | |
| Inp | 830.63 | NIST | |
| Inp | 832.99 | NIST | |
| Inp | 841.00 | NIST | |
| Inp | 834.00 | NIST | |
| Inp | 828.00 | NIST | |
| Inp | 833.00 | NIST | |
| Inp | 843.00 | NIST | |
| Inp | 833.00 | NIST | |
| Inp | 836.00 | NIST | |
| Inp | 834.00 | NIST | |
| Inp | 827.00 | NIST | |
| Inp | 831.70 | NIST | |
| Inp | 834.00 | NIST | |
| Inp | 825.00 | NIST | |
| Inp | 835.00 | NIST | |
| Inp | 837.90 | NIST | |
| Inp | 841.40 | NIST | |
| Inp | 844.00 | NIST | |
| Inp | 846.20 | NIST | |
| Inp | 825.00 | NIST | |
| Inp | 824.00 | NIST | |
| Inp | 837.00 | NIST | |
| Inp | 839.00 | NIST | |
| Inp | 834.00 | NIST | |
| Inp | 831.00 | NIST | |
| Inp | 827.00 | NIST | |
| Inp | 827.00 | NIST | |
| Inp | 840.00 | NIST | |
| Inp | 837.00 | NIST | |
| Inp | 827.00 | NIST | |
| Inp | 850.00 | NIST | |
| Inp | 840.00 | NIST | |
| Inp | 846.00 | NIST | |
| Inp | Outlier 867.90 | NIST | |
| Inp | 834.30 | NIST | |
| Inp | 837.00 | NIST | |
| Inp | 834.00 | NIST | |
| Inp | 836.00 | NIST | |
| Inp | 832.00 | NIST | |
| Inp | 839.00 | NIST | |
| Inp | 827.00 | NIST | |
| Inp | 840.00 | NIST | |
| I | [885.00; 925.20] |
|
|
| I | 920.00 | NIST | |
| I | 915.00 | NIST | |
| I | 920.00 | NIST | |
| I | 925.20 | NIST | |
| I | 905.50 | NIST | |
| I | 910.10 | NIST | |
| I | 920.00 | NIST | |
| I | Outlier 885.00 | NIST | |
| I | 920.00 | NIST | |
| I | 910.10 | NIST | |
| S°gas | 382.67 | J/mol×K | NIST |
| S°liquid | [280.91; 281.60] | J/mol×K |
|
| S°liquid | 280.91 | J/mol×K | NIST |
| S°liquid | 281.60 | J/mol×K | NIST |
| Tboil | [402.00; 410.00] | K |
|
| Tboil | 404.90 | K | KDB |
| Tboil | 405.00 | K | NIST |
| Tboil | 405.00 | K | NIST |
| Tboil | 405.00 ± 1.00 | K | NIST |
| Tboil | 405.00 ± 2.00 | K | NIST |
| Tboil | 406.00 ± 4.00 | K | NIST |
| Tboil | 406.00 ± 4.00 | K | NIST |
| Tboil | Outlier 409.00 ± 4.00 | K | NIST |
| Tboil | 405.00 ± 1.00 | K | NIST |
| Tboil | 405.00 ± 3.00 | K | NIST |
| Tboil | 404.00 ± 4.00 | K | NIST |
| Tboil | 404.90 ± 0.40 | K | NIST |
| Tboil | 404.93 ± 0.20 | K | NIST |
| Tboil | 404.93 ± 0.20 | K | NIST |
| Tboil | 405.00 ± 0.40 | K | NIST |
| Tboil | 403.70 ± 1.00 | K | NIST |
| Tboil | 405.00 ± 0.20 | K | NIST |
| Tboil | 404.85 ± 0.30 | K | NIST |
| Tboil | 404.92 ± 0.30 | K | NIST |
| Tboil | 404.35 ± 0.50 | K | NIST |
| Tboil | 404.93 ± 0.01 | K | NIST |
| Tboil | 405.10 ± 0.50 | K | NIST |
| Tboil | 405.00 ± 0.25 | K | NIST |
| Tboil | 404.93 ± 0.15 | K | NIST |
| Tboil | 404.93 ± 0.10 | K | NIST |
| Tboil | 403.15 ± 0.20 | K | NIST |
| Tboil | 403.55 ± 0.50 | K | NIST |
| Tboil | 404.80 ± 0.80 | K | NIST |
| Tboil | 404.75 ± 0.50 | K | NIST |
| Tboil | 405.00 ± 2.00 | K | NIST |
| Tboil | 404.00 ± 2.00 | K | NIST |
| Tboil | 402.65 ± 1.50 | K | NIST |
| Tboil | 405.05 ± 0.60 | K | NIST |
| Tboil | 403.60 ± 1.50 | K | NIST |
| Tboil | 405.00 ± 0.30 | K | NIST |
| Tboil | 403.15 ± 3.00 | K | NIST |
| Tboil | 402.00 ± 4.00 | K | NIST |
| Tboil | Outlier 410.00 ± 4.00 | K | NIST |
| Tboil | 403.00 ± 3.00 | K | NIST |
| Tboil | 402.00 ± 3.00 | K | NIST |
| Tc | [605.90; 609.00] | K |
|
| Tc | 605.90 | K | DIPPR Project 851 - Thirty Years of Vapor-Liquid Critical Point Measurements and Experimental Technique Development |
| Tc | 606.90 | K | Gas-Liquid Critical Temperatures of Some Alkenes, Amines, and Cyclic Hydrocarbons |
| Tc | 609.00 | K | KDB |
| Tc | 609.00 | K | NIST |
| Tfus | [158.40; 162.00] | K |
|
| Tfus | 161.80 | K | KDB |
| Tfus | 162.00 | K | Aq. Solubility Prediction |
| Tfus | Outlier 158.40 ± 1.40 | K | NIST |
| Tfus | 161.85 ± 0.05 | K | NIST |
| Tfus | 161.80 ± 0.01 | K | NIST |
| Tfus | 161.75 ± 0.10 | K | NIST |
| Tfus | 159.35 ± 0.30 | K | NIST |
| Tfus | 161.75 ± 1.50 | K | NIST |
| Ttriple | [161.40; 161.84] | K |
|
| Ttriple | 161.84 ± 0.05 | K | NIST |
| Ttriple | 161.40 ± 0.20 | K | NIST |
| Ttriple | 161.84 ± 0.05 | K | NIST |
| Ttriple | 161.40 ± 0.20 | K | NIST |
| Vc | 0.450 | m3/kmol | KDB |
| Zc | 0.2666120 | KDB |
| Property | Value | Unit | Temperature (K) | Source |
|---|---|---|---|---|
| Pvap | [1.33; 202.64] | kPa | [291.27; 433.70] |
The Yaws Handbook of Vapor Pressure
|
| Equation | ln(Pvp) = A + B/(T + C) | |||
| Coefficient A | 1.40223e+01 | |||
| Coefficient B | -3.39182e+03 | |||
| Coefficient C | -4.43220e+01 | |||
| Temperature range, min. | 291.27 | |||
| Temperature range, max. | 433.70 | |||
| Pvap | 1.33 | kPa | 291.27 | Calculated Property |
| Pvap | 3.05 | kPa | 307.10 | Calculated Property |
| Pvap | 6.35 | kPa | 322.92 | Calculated Property |
| Pvap | 12.21 | kPa | 338.75 | Calculated Property |
| Pvap | 21.97 | kPa | 354.57 | Calculated Property |
| Pvap | 37.35 | kPa | 370.40 | Calculated Property |
| Pvap | 60.45 | kPa | 386.22 | Calculated Property |
| Pvap | 93.76 | kPa | 402.05 | Calculated Property |
| Pvap | 140.11 | kPa | 417.87 | Calculated Property |
| Pvap | 202.64 | kPa | 433.70 | Calculated Property |
| Pvap | [3.59e-07; 3033.23] | kPa | [161.84; 609.15] |
KDB Vapor Pressure Data
|
| Equation | ln(Pvp) = A + B/T + C*ln(T) + D*T^2 | |||
| Coefficient A | 7.23704e+01 | |||
| Coefficient B | -7.17302e+03 | |||
| Coefficient C | -8.45462e+00 | |||
| Coefficient D | 4.40351e-06 | |||
| Temperature range, min. | 161.84 | |||
| Temperature range, max. | 609.15 | |||
| Pvap | 3.59e-07 | kPa | 161.84 | Calculated Property |
| Pvap | 1.35e-03 | kPa | 211.54 | Calculated Property |
| Pvap | 0.16 | kPa | 261.24 | Calculated Property |
| Pvap | 3.32 | kPa | 310.94 | Calculated Property |
| Pvap | 26.41 | kPa | 360.64 | Calculated Property |
| Pvap | 116.75 | kPa | 410.35 | Calculated Property |
| Pvap | 355.10 | kPa | 460.05 | Calculated Property |
| Pvap | 843.49 | kPa | 509.75 | Calculated Property |
| Pvap | 1694.41 | kPa | 559.45 | Calculated Property |
| Pvap | 3033.23 | kPa | 609.15 | Calculated Property |
Find more compounds similar to Cyclohexane, ethyl-.
Note: Cheméo is only indexing the data, follow the source links to retrieve the latest data. The source is also providing more information like the publication year, authors and more.
Take the time to validate and double check the source of the data.
Outlier This icon means
that the value is more than 2 standard deviations away from the
property mean.
These property values are available through the Cheméo API. A free account gives you an access key.