Chemical Properties of 1,3-Cyclopentadiene, 1-methyl- (CAS 96-39-9)

1,3-Cyclopentadiene, 1-methyl-

InChI
InChI=1S/C6H8/c1-6-4-2-3-5-6/h2-4H,5H2,1H3
InChI Key
NFWSQSCIDYBUOU-UHFFFAOYSA-N
Formula
C6H8
SMILES
CC1=CC=CC1
Molecular Weight1
80.13
CAS
96-39-9
Other Names
  • 1-Methyl-1,3-cyclopentadiene
  • 1-Methylcyclopentadiene
  • Methylcyclopentadiene
  • l,3-Cyclopentadiene,1-methyl-
Cheméo is a service of Céondo GmbH, since 2007, we provide simulation, modelling and software development services for the industry. Do not hesitate to contact us for your projects.

Physical Properties

Property Value Unit Source
ΔfH°gas 116.42 kJ/mol Relay (1.0) Calculated Property
ΔfusH° 6.22 kJ/mol Joback Calculated Property
IE [8.40; 8.43] eV Show Hide
IE 8.40 ± 0.02 eV NIST
IE 8.40 ± 0.02 eV NIST
IE 8.43 ± 0.05 eV NIST
IE 8.40 eV NIST
IE 8.40 eV NIST
logPoct/wat 1.893 Crippen Calculated Property
McVol 75.940 ml/mol McGowan Calculated Property
Inp [623.00; 653.80]   Show Hide
Inp 644.00 NIST
Inp 642.00 NIST
Inp 630.00 NIST
Inp 627.50 NIST
Inp 653.80 NIST
Inp 652.80 NIST
Inp 644.00 NIST
Inp 641.00 NIST
Inp 644.00 NIST
Inp 642.00 NIST
Inp 626.00 NIST
Inp 626.30 NIST
Inp 623.00 NIST
Inp 626.00 NIST
Inp 628.00 NIST
Inp 626.00 NIST
Inp 626.00 NIST
Ip [844.50; 844.50]   Show Hide
Ip 844.50 NIST
Ip 844.50 NIST
Tboil 349.82 K Relay (1.0) Calculated Property
Tfus 170.98 K Relay (1.0) Calculated Property
Ttriple 130.20 ± 0.10 K NIST

Cheméo can also estimate Critical Temperature, Critical Pressure, Critical Volume, Enthalpy of vaporization at standard conditions, Standard Gibbs free energy of formation, Acentric Factor, Log10 of Water solubility in mol/l for this compound, but they fall outside the models' validated range, so they are not shown here. Open the prediction tool to compute them on demand.

Correlations

Property Value Unit Temperature (K) Source
Cp,gas [86.87; 239.87] J/mol×K [273.00; 1000.00] Joback Predicted correlation Show Hide
EquationY = A + B·T + C·T² + D·T³ + E·T⁴
Y is Cp,gas in J/mol×K, T in K
Coefficient A-3.91300e+01
Coefficient B5.60520e-01
Coefficient C-3.92920e-04
Coefficient D1.11400e-07
Coefficient E0.00000e+00
Temperature range, min.273.00
Temperature range, max.1000.00
Cp,gas 86.87 J/mol×K 273.00 Calculated Property
Cp,gas 114.92 J/mol×K 353.78 Calculated Property
Cp,gas 139.39 J/mol×K 434.56 Calculated Property
Cp,gas 160.62 J/mol×K 515.33 Calculated Property
Cp,gas 178.98 J/mol×K 596.11 Calculated Property
Cp,gas 194.80 J/mol×K 676.89 Calculated Property
Cp,gas 208.45 J/mol×K 757.67 Calculated Property
Cp,gas 220.28 J/mol×K 838.44 Calculated Property
Cp,gas 230.63 J/mol×K 919.22 Calculated Property
Cp,gas 239.87 J/mol×K 1000.00 Calculated Property
Property Value Unit Temperature (K) Source
η [0.0018579; 0.0001998] Pa×s [186.56; 393.38] Joback Predicted correlation Show Hide
EquationY = exp(A + B/T + C·ln(T) + D·T^E)
Y is η in Pa×s, T in K
Coefficient A-1.05293e+01
Coefficient B7.91210e+02
Coefficient C0.00000e+00
Coefficient D0.00000e+00
Coefficient E0.00000e+00
CommentLiquid phase. Joback/Reid (1987), valid from Tf to 0.7·Tc.
Temperature range, min.186.56
Temperature range, max.393.38
η 0.0018579 Pa×s 186.56 Calculated Property
η 0.0011669 Pa×s 209.54 Calculated Property
η 0.0008034 Pa×s 232.52 Calculated Property
η 0.0005916 Pa×s 255.50 Calculated Property
η 0.0004582 Pa×s 278.48 Calculated Property
η 0.0003690 Pa×s 301.46 Calculated Property
η 0.0003064 Pa×s 324.44 Calculated Property
η 0.0002607 Pa×s 347.42 Calculated Property
η 0.0002264 Pa×s 370.40 Calculated Property
η 0.0001998 Pa×s 393.38 Calculated Property
Property Value Unit Temperature (K) Source
Pvap [7.85e-06; 4337.36] kPa [150.00; 541.00] KDB Vapor Pressure Data Show Hide
Equationln(Y) = A + B/T + C·ln(T) + D·T² + E/T²
Y is Pvap in kPa, T in K
Coefficient A5.35325e+01
Coefficient B-5.50987e+03
Coefficient C-5.71400e+00
Coefficient D3.37471e-06
Coefficient E0.00000e+00
Temperature range, min.150.00
Temperature range, max.541.00
Pvap 7.85e-06 kPa 150.00 Calculated Property
Pvap 7.38e-03 kPa 193.44 Calculated Property
Pvap 0.46 kPa 236.89 Calculated Property
Pvap 6.95 kPa 280.33 Calculated Property
Pvap 46.60 kPa 323.78 Calculated Property
Pvap 188.05 kPa 367.22 Calculated Property
Pvap 544.11 kPa 410.67 Calculated Property
Pvap 1255.03 kPa 454.11 Calculated Property
Pvap 2469.60 kPa 497.56 Calculated Property
Pvap 4337.36 kPa 541.00 Calculated Property

Similar Compounds

1,4,6-Octatriene, 2,7-dimethyl. 1,3-Cyclopentadiene, 1-ethyl. 1,3-Cyclopentadiene, 1,2-dimethyl-. 1,4-Hexadiene, 2-methyl-. 1,4-Hexadiene, 4-methyl-. 2,6-Dimethyl 1,4,6(7)-octatriene (cis-6(7)). 1,4-Cyclohexadiene, 1-methyl-. 4-Methyl-1,4-heptadiene. 1,3-Cyclopentadiene, 1-propyl. 2,6-Dimethyl-1,3,6-heptatriene. 1,3-Cyclopentadiene, 2-ethyl. 1,4-Hexadiene, 2,5-dimethyl-. 1,2,3-Trimethylcyclopentadiene. 1,3-Cyclopentadiene, 1-butyl. 1,3-Cyclopentadiene, 1-hexyl.

Find more compounds similar to 1,3-Cyclopentadiene, 1-methyl-.

Sources

Note: Cheméo is only indexing the data, follow the source links to retrieve the latest data. The source is also providing more information like the publication year, authors and more. Take the time to validate and double check the source of the data.
Calculated This icon marks a calculated value or equation: a prediction, not a measurement.
These property values are available through the Cheméo API. A free account gives you an access key.