| Property | Value | Unit | Source |
|---|---|---|---|
| ω | 0.7080 | PSRK revision IV (2005), critical constants and acentric factors of 1000 components Compiled value | |
| ΔcH°solid | [-3192.30; -3192.00] | kJ/mol |
|
| ΔcH°solid | -3192.00 ± 0.40 | kJ/mol | NIST |
| ΔcH°solid | -3192.30 | kJ/mol | NIST |
| ΔfH°gas | 71.80 | kJ/mol | Relay (1.0) Calculated Property |
| ΔfH°solid | [-26.30; -26.00] | kJ/mol |
|
| ΔfH°solid | -26.00 ± 0.40 | kJ/mol | NIST |
| ΔfH°solid | -26.30 | kJ/mol | NIST |
| ΔfusH° | 21.51 | kJ/mol | Joback Calculated Property |
| ΔsubH° | 89.00 ± 0.70 | kJ/mol | NIST |
| ΔvapH° | 64.52 | kJ/mol | Relay (1.0) Calculated Property |
| IE | [8.27; 8.66] | eV |
|
| IE | 8.27 ± 0.01 | eV | NIST |
| IE | 8.66 | eV | NIST |
| IE | 8.43 | eV | NIST |
| log10WS | [-1.96; -1.96] |
|
|
| log10WS | -1.96 | Aq. Solubility Prediction | |
| log10WS | -1.96 | Estimated Solubility | |
| logPoct/wat | 1.177 | Crippen Calculated Property | |
| McVol | 99.040 | ml/mol | McGowan Calculated Property |
| Pc | 5501.95 | kPa | PSRK revision IV (2005), critical constants and acentric factors of 1000 components Compiled value |
| Inp | [241.10; 1402.00] |
|
|
| Inp | 1402.00 | NIST | |
| Inp | 241.10 | NIST | |
| Inp | 241.10 | NIST | |
| Tboil | 557.20 | K | NIST |
| Tc | 800.00 | K | PSRK revision IV (2005), critical constants and acentric factors of 1000 components Compiled value |
| Tfus | [342.00; 345.15] | K |
|
| Tfus | 345.15 | K | Jean-Claude Bradley Open Melting Point Dataset (2014, CC0) Compiled value |
| Tfus | 344.15 ± 0.50 | K | NIST |
| Tfus | 344.30 ± 0.20 | K | NIST |
| Tfus | 343.75 ± 0.30 | K | NIST |
| Tfus | 342.00 ± 1.50 | K | NIST |
| Tfus | 344.60 ± 0.15 | K | NIST |
| Tfus | 342.45 ± 0.30 | K | NIST |
| Tfus | 342.90 ± 0.10 | K | NIST |
| Vc | 0.370 | m3/kmol | PSRK revision IV (2005), critical constants and acentric factors of 1000 components Compiled value |
Cheméo can also estimate Standard Gibbs free energy of formation for this compound, but it falls outside the models' validated range, so it is not shown here. Open the prediction tool to compute it on demand.
| Property | Value | Unit | Temperature (K) | Source |
|---|---|---|---|---|
| Cp,solid | [164.40; 168.20] | J/mol×K | [297.90; 298.00] | |
| Cp,solid | 168.20 | J/mol×K | 297.90 | NIST |
| Cp,solid | 164.40 | J/mol×K | 298.00 | NIST |
| ΔfusH | [16.11; 16.11] | kJ/mol | [342.50; 344.40] | |
| ΔfusH | 16.11 | kJ/mol | 342.50 | NIST |
| ΔfusH | 16.11 | kJ/mol | 342.50 | NIST |
| ΔfusH | 16.11 | kJ/mol | 344.40 | NIST |
| ΔsubH | [79.90; 90.00] | kJ/mol | [223.00; 327.50] | |
| ΔsubH | 90.00 ± 4.20 | kJ/mol | 223.00 | NIST |
| ΔsubH | 82.00 ± 2.00 | kJ/mol | 313.00 | NIST |
| ΔsubH | 82.00 ± 2.00 | kJ/mol | 313.00 | NIST |
| ΔsubH | 79.90 ± 1.70 | kJ/mol | 314.50 | NIST |
| ΔsubH | 87.20 ± 0.70 | kJ/mol | 327.50 | NIST |
| ΔvapH | [59.30; 64.80] | kJ/mol | [467.50; 488.00] | |
| ΔvapH | 64.80 | kJ/mol | 467.50 | NIST |
| ΔvapH | 59.30 | kJ/mol | 488.00 | NIST |
| Psub | [3.64e-04; 8.82e-03] | kPa | [308.15; 338.15] | |
| Psub | 3.64e-04 | kPa | 308.15 | Triacetone triperoxide thermogravimetric study of vapor pressure and enthalpy of sublimation in 303 338 K temperature range |
| Psub | 6.21e-04 | kPa | 313.15 | Triacetone triperoxide thermogravimetric study of vapor pressure and enthalpy of sublimation in 303 338 K temperature range |
| Psub | 1.09e-03 | kPa | 318.15 | Triacetone triperoxide thermogravimetric study of vapor pressure and enthalpy of sublimation in 303 338 K temperature range |
| Psub | 1.89e-03 | kPa | 323.15 | Triacetone triperoxide thermogravimetric study of vapor pressure and enthalpy of sublimation in 303 338 K temperature range |
| Psub | 3.23e-03 | kPa | 328.15 | Triacetone triperoxide thermogravimetric study of vapor pressure and enthalpy of sublimation in 303 338 K temperature range |
| Psub | 8.82e-03 | kPa | 338.15 | Triacetone triperoxide thermogravimetric study of vapor pressure and enthalpy of sublimation in 303 338 K temperature range |
| ΔfusS | 47.00 | J/mol×K | 342.50 | NIST |
| Property | Value | Unit | Temperature (K) | Source |
|---|---|---|---|---|
| Cp,gas | [125.60; 289.51] | J/mol×K | [273.00; 1000.00] |
Joback Predicted correlation
|
| Equation | Y = A + B·T + C·T² + D·T³ + E·T⁴ Y is Cp,gas in J/mol×K, T in K | |||
| Coefficient A | -1.01900e+01 | |||
| Coefficient B | 5.96660e-01 | |||
| Coefficient C | -3.88560e-04 | |||
| Coefficient D | 9.16000e-08 | |||
| Coefficient E | 0.00000e+00 | |||
| Temperature range, min. | 273.00 | |||
| Temperature range, max. | 1000.00 | |||
| Cp,gas | 125.60 | J/mol×K | 273.00 | Calculated Property |
| Cp,gas | 156.32 | J/mol×K | 353.78 | Calculated Property |
| Cp,gas | 183.23 | J/mol×K | 434.56 | Calculated Property |
| Cp,gas | 206.64 | J/mol×K | 515.33 | Calculated Property |
| Cp,gas | 226.81 | J/mol×K | 596.11 | Calculated Property |
| Cp,gas | 244.06 | J/mol×K | 676.89 | Calculated Property |
| Cp,gas | 258.66 | J/mol×K | 757.67 | Calculated Property |
| Cp,gas | 270.91 | J/mol×K | 838.44 | Calculated Property |
| Cp,gas | 281.10 | J/mol×K | 919.22 | Calculated Property |
| Cp,gas | 289.51 | J/mol×K | 1000.00 | Calculated Property |
| Property | Value | Unit | Temperature (K) | Source |
|---|---|---|---|---|
| Pvap | [1.33; 202.67] | kPa | [423.96; 587.58] |
The Yaws Handbook of Vapor Pressure
|
| Equation | ln(Y) = A + B/(T + C) Y is Pvap in kPa, T in K | |||
| Coefficient A | 1.71477e+01 | |||
| Coefficient B | -6.49919e+03 | |||
| Coefficient C | -3.84840e+01 | |||
| Temperature range, min. | 423.96 | |||
| Temperature range, max. | 587.58 | |||
| Pvap | 1.33 | kPa | 423.96 | Calculated Property |
| Pvap | 2.85 | kPa | 442.14 | Calculated Property |
| Pvap | 5.70 | kPa | 460.32 | Calculated Property |
| Pvap | 10.78 | kPa | 478.50 | Calculated Property |
| Pvap | 19.36 | kPa | 496.68 | Calculated Property |
| Pvap | 33.27 | kPa | 514.86 | Calculated Property |
| Pvap | 54.94 | kPa | 533.04 | Calculated Property |
| Pvap | 87.55 | kPa | 551.22 | Calculated Property |
| Pvap | 135.13 | kPa | 569.40 | Calculated Property |
| Pvap | 202.67 | kPa | 587.58 | Calculated Property |
| Pvap | [0.01; 268.08] | kPa | [344.65; 600.15] |
KDB Vapor Pressure Data
|
| Equation | ln(Y) = A + B/T + C·ln(T) + D·T² + E/T² Y is Pvap in kPa, T in K | |||
| Coefficient A | 1.36243e+02 | |||
| Coefficient B | -1.36758e+04 | |||
| Coefficient C | -1.74694e+01 | |||
| Coefficient D | 1.08034e-05 | |||
| Coefficient E | 0.00000e+00 | |||
| Temperature range, min. | 344.65 | |||
| Temperature range, max. | 600.15 | |||
| Pvap | 0.01 | kPa | 344.65 | Calculated Property |
| Pvap | 0.09 | kPa | 373.04 | Calculated Property |
| Pvap | 0.44 | kPa | 401.43 | Calculated Property |
| Pvap | 1.64 | kPa | 429.82 | Calculated Property |
| Pvap | 5.07 | kPa | 458.21 | Calculated Property |
| Pvap | 13.52 | kPa | 486.59 | Calculated Property |
| Pvap | 32.15 | kPa | 514.98 | Calculated Property |
| Pvap | 69.75 | kPa | 543.37 | Calculated Property |
| Pvap | 140.75 | kPa | 571.76 | Calculated Property |
| Pvap | 268.08 | kPa | 600.15 | Calculated Property |
| Pvap | [0.13; 99.73] | kPa | [377.00; 557.70] |
NIST
|
| Equation | ln(Y) = A + B/(T + C) Y is Pvap in kPa, T in K | |||
| Coefficient A | 1.77104e+01 | |||
| Coefficient B | -7.06301e+03 | |||
| Coefficient C | -1.88650e+01 | |||
| Reference | Stull, 1947 | |||
| Comment | Coefficents calculated by NIST from author's data. | |||
| Temperature range, min. | 377.00 | |||
| Temperature range, max. | 557.70 | |||
| Pvap | 0.13 | kPa | 377.00 | Calculated Property |
| Pvap | 0.38 | kPa | 397.08 | Calculated Property |
| Pvap | 0.98 | kPa | 417.16 | Calculated Property |
| Pvap | 2.29 | kPa | 437.23 | Calculated Property |
| Pvap | 4.96 | kPa | 457.31 | Calculated Property |
| Pvap | 10.04 | kPa | 477.39 | Calculated Property |
| Pvap | 19.16 | kPa | 497.47 | Calculated Property |
| Pvap | 34.71 | kPa | 517.54 | Calculated Property |
| Pvap | 60.05 | kPa | 537.62 | Calculated Property |
| Pvap | 99.73 | kPa | 557.70 | Calculated Property |
Find more compounds similar to 2-Nitroaniline.
Note: Cheméo is only indexing the data, follow the source links to retrieve the latest data. The source is also providing more information like the publication year, authors and more.
Take the time to validate and double check the source of the data.
Calculated This icon marks a calculated value or equation: a prediction, not a measurement.
Compiled This icon marks a compiled value or equation: taken from a data compilation such as ChemSep, not from an original measurement report.
These property values are available through the Cheméo API. A free account gives you an access key.