Chemical Properties of 2-Butene-1,4-diol, (Z)- (CAS 6117-80-2)

2-Butene-1,4-diol, (Z)-

InChI
InChI=1S/C4H8O2/c5-3-1-2-4-6/h1-2,5-6H,3-4H2/b2-1-
InChI Key
ORTVZLZNOYNASJ-UPHRSURJSA-N
Formula
C4H8O2
SMILES
OCC=CCO
Molecular Weight1
88.11
CAS
6117-80-2
Other Names
  • (Z)-2-Butene-1,4-diol
  • cis-1,4-Dihydroxy-2-butene
  • cis-2-Butene-1,4-Diol
  • cis-Butenediol
Cheméo is a service of Céondo GmbH, since 2007, we provide simulation, modelling and software development services for the industry. Do not hesitate to contact us for your projects.

Physical Properties

Property Value Unit Source
ω 0.6411 Relay (1.0) Calculated Property
ΔfG° -210.62 kJ/mol Joback Calculated Property
ΔfH°gas -351.28 kJ/mol Relay (1.0) Calculated Property
ΔfusH° 14.49 kJ/mol Joback Calculated Property
ΔvapH° 82.50 kJ/mol Relay (1.0) Calculated Property
IE 9.24 eV Relay (1.0) Calculated Property
logPoct/wat -0.473 Crippen Calculated Property
McVol 74.660 ml/mol McGowan Calculated Property
Pc 5359.18 kPa Joback Calculated Property
Tboil 508.20 K NIST
Tc 692.96 K Relay (1.0) Calculated Property
Tfus 284.20 ± 0.50 K NIST
Vc 0.254 m3/kmol Relay (1.0) Calculated Property

Cheméo can also estimate Log10 of Water solubility in mol/l for this compound, but it falls outside the models' validated range, so it is not shown here. Open the prediction tool to compute it on demand.

Temperature Dependent Properties

Property Value Unit Temperature (K) Source
ΔvapH 74.70 kJ/mol 440.50 NIST

Pressure Dependent Properties

Property Value Unit Pressure (kPa) Source
Tboilr 405.20 K 2.10 NIST

Correlations

Property Value Unit Temperature (K) Source
Cp,gas [101.34; 232.45] J/mol×K [273.00; 1000.00] Joback Predicted correlation Show Hide
EquationY = A + B·T + C·T² + D·T³ + E·T⁴
Y is Cp,gas in J/mol×K, T in K
Coefficient A-4.34800e+00
Coefficient B4.71800e-01
Coefficient C-3.38400e-04
Coefficient D1.03400e-07
Coefficient E0.00000e+00
Temperature range, min.273.00
Temperature range, max.1000.00
Cp,gas 101.34 J/mol×K 273.00 Calculated Property
Cp,gas 124.79 J/mol×K 353.78 Calculated Property
Cp,gas 145.26 J/mol×K 434.56 Calculated Property
Cp,gas 163.07 J/mol×K 515.33 Calculated Property
Cp,gas 178.55 J/mol×K 596.11 Calculated Property
Cp,gas 192.03 J/mol×K 676.89 Calculated Property
Cp,gas 203.83 J/mol×K 757.67 Calculated Property
Cp,gas 214.28 J/mol×K 838.44 Calculated Property
Cp,gas 223.72 J/mol×K 919.22 Calculated Property
Cp,gas 232.45 J/mol×K 1000.00 Calculated Property
Property Value Unit Temperature (K) Source
η [0.0374705; 0.0001779] Pa×s [284.20; 451.56] Joback Predicted correlation Show Hide
EquationY = exp(A + B/T + C·ln(T) + D·T^E)
Y is η in Pa×s, T in K
Coefficient A-1.77195e+01
Coefficient B4.10250e+03
Coefficient C0.00000e+00
Coefficient D0.00000e+00
Coefficient E0.00000e+00
Temperature range, min.284.20
Temperature range, max.451.56
η 0.0374705 Pa×s 284.20 Calculated Property
η 0.0154412 Pa×s 302.80 Calculated Property
η 0.0070506 Pa×s 321.39 Calculated Property
η 0.0035076 Pa×s 339.99 Calculated Property
η 0.0018761 Pa×s 358.58 Calculated Property
η 0.0010673 Pa×s 377.18 Calculated Property
η 0.0006402 Pa×s 395.77 Calculated Property
η 0.0004021 Pa×s 414.37 Calculated Property
η 0.0002628 Pa×s 432.97 Calculated Property
η 0.0001779 Pa×s 451.56 Calculated Property
Property Value Unit Temperature (K) Source
Pvap [1.33; 202.66] kPa [397.27; 531.78] The Yaws Handbook of Vapor Pressure Show Hide
Equationln(Y) = A + B/(T + C)
Y is Pvap in kPa, T in K
Coefficient A2.06264e+01
Coefficient B-8.33944e+03
Coefficient C1.27540e+01
Temperature range, min.397.27
Temperature range, max.531.78
Pvap 1.33 kPa 397.27 Calculated Property
Pvap 2.73 kPa 412.22 Calculated Property
Pvap 5.31 kPa 427.16 Calculated Property
Pvap 9.90 kPa 442.11 Calculated Property
Pvap 17.74 kPa 457.05 Calculated Property
Pvap 30.66 kPa 472.00 Calculated Property
Pvap 51.28 kPa 486.94 Calculated Property
Pvap 83.27 kPa 501.89 Calculated Property
Pvap 131.54 kPa 516.83 Calculated Property
Pvap 202.66 kPa 531.78 Calculated Property
Pvap [1.75e-04; 5223.99] kPa [284.15; 677.88] KDB Vapor Pressure Data Show Hide
Equationln(Y) = A + B/T + C·ln(T) + D·T² + E/T²
Y is Pvap in kPa, T in K
Coefficient A2.11722e+02
Coefficient B-1.71176e+04
Coefficient C-2.86125e+01
Coefficient D1.87469e-05
Coefficient E0.00000e+00
Temperature range, min.284.15
Temperature range, max.677.88
Pvap 1.75e-04 kPa 284.15 Calculated Property
Pvap 0.01 kPa 327.90 Calculated Property
Pvap 0.34 kPa 371.65 Calculated Property
Pvap 3.45 kPa 415.39 Calculated Property
Pvap 20.41 kPa 459.14 Calculated Property
Pvap 85.14 kPa 502.89 Calculated Property
Pvap 282.17 kPa 546.64 Calculated Property
Pvap 806.38 kPa 590.38 Calculated Property
Pvap 2104.31 kPa 634.13 Calculated Property
Pvap 5223.99 kPa 677.88 Calculated Property

Similar Compounds

2-Butene-1,4-diol. 2-Buten-1-ol, (E)-. 2-Buten-1-ol. 2-Buten-1-ol, (Z)-. 2-Penten-4-yn-1-ol. 2,4-Hexadien-1-ol. Hex-2-en-4-in-1-ol. 2-Penten-1-ol, (E)-. 2-Penten-1-ol. (Z)-2-Penten-1-ol. trans-2-Penten-1-ol. 2-Penten-1-ol, (Z)-. (E)-2-Penten-1-ol. Pent-2-en-1-ol. Prenol.

Find more compounds similar to 2-Butene-1,4-diol, (Z)-.

Sources

Note: Cheméo is only indexing the data, follow the source links to retrieve the latest data. The source is also providing more information like the publication year, authors and more. Take the time to validate and double check the source of the data.
These property values are available through the Cheméo API. A free account gives you an access key.