| Property | Value | Unit | Source |
|---|---|---|---|
| ΔcH°solid | [-2610.00; -2560.00] | kJ/mol |
|
| ΔcH°solid | -2571.90 ± 1.70 | kJ/mol | NISTFinch and Smith, 1983 |
| ΔcH°solid | -2575.90 ± 1.30 | kJ/mol | NISTVorob'yov, Privalova, et al., 1960 |
| ΔcH°solid | -2560.00 | kJ/mol | NIST Handrick, 1956 |
| Stegeman, G. Univ. of Pittsburg 1945 | |||
| ΔcH°solid | -2569.10 ± 2.60 | kJ/mol | NIST Badoche, 1942 |
| Reanalyzed by Cox and Pilcher, 1970, Original value = -2573.0 kJ/mol | |||
| ΔcH°solid | -2567.60 ± 2.60 | kJ/mol | NIST Burlot, 1939 |
| Reanalyzed by Cox and Pilcher, 1970, Original value = -2584.3 kJ/mol | |||
| ΔcH°solid | -2578.60 ± 2.50 | kJ/mol | NIST Milone and Rossignoli, 1932 |
| Reanalyzed by Cox and Pilcher, 1970, Original value = -2596.8 kJ/mol | |||
| ΔcH°solid | -2564.88 | kJ/mol | NIST Rinkenbach, 1930 |
| Author hf298_condensed[kcal/mol]=-55.98 | |||
| ΔcH°solid | Outlier -2610.00 | kJ/mol | NISTGarner and Abernethy, 1921 |
| ΔfH°gas | -79.15 | kJ/mol | Relay (1.0) Calculated Property |
| ΔfH°solid | [-224.90; -214.00] | kJ/mol |
|
| ΔfH°solid | -217.90 ± 2.00 | kJ/mol | NISTFinch and Smith, 1983 |
| ΔfH°solid | -214.00 ± 1.30 | kJ/mol | NISTVorob'yov, Privalova, et al., 1960 |
| ΔfH°solid | -224.90 | kJ/mol | NIST Rinkenbach, 1930 |
| Author hf298_condensed[kcal/mol]=-55.98 | |||
| ΔfusH° | 44.42 | kJ/mol | Joback Calculated Property |
| ΔsubH° | 105.10 ± 1.60 | kJ/mol | NISTCundall, Frank Palmer, et al., 1978 |
| ΔvapH° | 87.79 | kJ/mol | Relay (1.0) Calculated Property |
| IE | 9.94 | eV | Relay (1.0) Calculated Property |
| log10WS | -2.83 | Aq. Solubility Prediction | |
| logPoct/wat | 1.117 | Crippen Calculated Property | |
| McVol | 129.770 | ml/mol | McGowan Calculated Property |
| Tboil | 531.52 | K | Relay (1.0) Calculated Property |
| Tfus | [393.40; 395.60] | K |
|
| Tfus | 395.40 | K | Jean-Claude Bradley Open Melting Point Dataset (2014, CC0) Compiled value |
| Tfus | 395.40 | K | Aq. Solubility Prediction |
| Tfus | 395.15 ± 0.20 | K | NIST Singh and Kumar, 1989 |
| Identification of composition in Table I probably. reversed | |||
| Tfus | 395.60 ± 2.00 | K | NISTKotula and Rabczuk, 1985 |
| Tfus | 394.10 ± 0.60 | K | NISTFarrell and Shahidi, 1979 |
| Tfus | 394.95 ± 0.30 | K | NISTAssal, 1966 |
| Tfus | 395.00 ± 2.00 | K | NISTBuechner, 1906 |
| Tfus | Outlier 393.40 ± 0.30 | K | NISTPhilip and Smith, 1905 |
Cheméo can also estimate Critical Temperature, Critical Pressure, Critical Volume, Standard Gibbs free energy of formation, Acentric Factor for this compound, but they fall outside the models' validated range, so they are not shown here. Open the prediction tool to compute them on demand.
| Property | Value | Unit | Temperature (K) | Source |
|---|---|---|---|---|
| Cp,solid | 239.70 | J/mol×K | 293.00 | NIST Taylor and Rinkenbach, 1924 |
| T = 90 to 395 K. | ||||
| ΔfusH | [17.10; 17.10] | kJ/mol | [394.10; 394.10] | |
| ΔfusH | 17.10 | kJ/mol | 394.10 | NISTFarrell, Shahidi, et al., 1979 |
| ΔfusH | 17.10 | kJ/mol | 394.10 | NISTDomalski and Hearing, 1996 |
| ΔfusH | 17.10 | kJ/mol | 394.10 | NISTDomalski and Hearing, 1996 |
| ΔvapH | [106.40; 106.40] | kJ/mol | [533.00; 533.00] | |
| ΔvapH | 106.40 | kJ/mol | 533.00 | NIST Stephenson and Malanowski, 1987 |
| The value of 106.4 kJ/mole from {R1987STE/MAL} is likely an enthalpy of sublimation | ||||
| ΔvapH | 106.40 | kJ/mol | 533.00 | NIST Stephenson and Malanowski, 1987 |
| The value of 106.4 kJ/mole from Stephenson and Malanowski, 1987 is likely an enthalpy of sublimation | ||||
| ΔfusS | 43.40 | J/mol×K | 394.10 | NISTFarrell, Shahidi, et al., 1979 |
| Property | Value | Unit | Temperature (K) | Source |
|---|---|---|---|---|
| Cp,gas | [179.01; 365.38] | J/mol×K | [273.00; 1000.00] |
Joback Predicted correlation
|
| Equation | Y = A + B·T + C·T² + D·T³ + E·T⁴ Y is Cp,gas in J/mol×K, T in K | |||
| Coefficient A | -3.20000e-01 | |||
| Coefficient B | 8.28580e-01 | |||
| Coefficient C | -6.91280e-04 | |||
| Coefficient D | 2.28400e-07 | |||
| Coefficient E | 0.00000e+00 | |||
| Temperature range, min. | 273.00 | |||
| Temperature range, max. | 1000.00 | |||
| Cp,gas | 179.01 | J/mol×K | 273.00 | Calculated Property |
| Cp,gas | 216.41 | J/mol×K | 353.78 | Calculated Property |
| Cp,gas | 247.95 | J/mol×K | 434.56 | Calculated Property |
| Cp,gas | 274.35 | J/mol×K | 515.33 | Calculated Property |
| Cp,gas | 296.34 | J/mol×K | 596.11 | Calculated Property |
| Cp,gas | 314.64 | J/mol×K | 676.89 | Calculated Property |
| Cp,gas | 329.97 | J/mol×K | 757.67 | Calculated Property |
| Cp,gas | 343.06 | J/mol×K | 838.44 | Calculated Property |
| Cp,gas | 354.62 | J/mol×K | 919.22 | Calculated Property |
| Cp,gas | 365.38 | J/mol×K | 1000.00 | Calculated Property |
| Property | Value | Unit | Temperature (K) | Source |
|---|---|---|---|---|
| Pvap | [0.28; 105.60] | kPa | [468.15; 598.15] |
KDB Vapor Pressure Data
|
| Equation | ln(Y) = A + B/T + C·ln(T) + D·T² + E/T² Y is Pvap in kPa, T in K | |||
| Coefficient A | 2.60634e+01 | |||
| Coefficient B | -1.28024e+04 | |||
| Coefficient C | -7.21084e-05 | |||
| Coefficient D | 4.74385e-11 | |||
| Coefficient E | 0.00000e+00 | |||
| Temperature range, min. | 468.15 | |||
| Temperature range, max. | 598.15 | |||
| Pvap | 0.28 | kPa | 468.15 | Calculated Property |
| Pvap | 0.63 | kPa | 482.59 | Calculated Property |
| Pvap | 1.36 | kPa | 497.04 | Calculated Property |
| Pvap | 2.81 | kPa | 511.48 | Calculated Property |
| Pvap | 5.59 | kPa | 525.93 | Calculated Property |
| Pvap | 10.71 | kPa | 540.37 | Calculated Property |
| Pvap | 19.85 | kPa | 554.82 | Calculated Property |
| Pvap | 35.64 | kPa | 569.26 | Calculated Property |
| Pvap | 62.18 | kPa | 583.71 | Calculated Property |
| Pvap | 105.60 | kPa | 598.15 | Calculated Property |
Find more compounds similar to Phenol, 2,4,6-trinitro-.
Note: Cheméo is only indexing the data, follow the source links to retrieve the latest data. The source is also providing more information like the publication year, authors and more.
Take the time to validate and double check the source of the data.
Outlier This icon means
that the value is more than 2 standard deviations away from the
property mean.
Calculated This icon marks a calculated value or equation: a prediction, not a measurement.
Compiled This icon marks a compiled value or equation: taken from a data compilation such as ChemSep, not from an original measurement report.
These property values are available through the Cheméo API. A free account gives you an access key.