Documentation / Cheméo RefData
Cheméo RefData
Cheméo RefData is one consistent set of values per compound, made for process simulation. Cheméo stores many values for each property, from many sources; RefData selects one value per constant and fits one equation per temperature-dependent property, so that they agree with one another: the vapour pressure curve passes through the critical point and, where it is measured, the normal boiling point, and the PR and SRK parameters reproduce that vapour pressure.
What a record holds
Constants, one value each, in Cheméo's units:
| Code | Property | Unit |
|---|---|---|
mw |
Molecular weight | g/mol |
tc, pc, vc |
Critical temperature, pressure, volume | K, kPa, m³/kmol |
zc |
Critical compressibility | |
af |
Acentric factor | |
tb, tf |
Normal boiling point, melting point | K |
hf, gf |
Enthalpy and Gibbs energy of formation, ideal gas | kJ/mol |
zra |
Rackett parameter |
Correlations, one equation each, valid on the temperature range it gives:
vapour pressure pvap (kPa), ideal gas heat capacity cpg and liquid heat capacity
cpl (J/mol×K), enthalpy of vaporization hvapt (kJ/mol), liquid density rhol
(kg/m³), liquid viscosity dvisc (Pa×s), liquid and vapour thermal conductivity
tcondl and tcondg (W/m×K), surface tension srf (N/m). The equations are the
DIPPR forms of Cheméo's correlation registry: dippr-100 to dippr-107, with T in
K.
Two equation-of-state blocks, PR and SRK: the critical temperature and pressure, the acentric factor, a Mathias-Copeman alpha function (c1, c2, c3) fitted to the RefData vapour pressure, a Péneloux volume shift, and the error of the vapour pressure the block reproduces.
Where each value comes from
Every constant and every fit says its basis:
- experimental: from the measurements Cheméo holds, combined into one value. The
measurements are weighted by their uncertainty, outliers are set aside, and
u95is the 95% uncertainty of the result. - compiled: from a data compilation (ChemSep, ChEDL) or from published correlations (the KDB, Yaws and NIST WebBook equations), used only where Cheméo has no measurement. A compiled value is never averaged with measured ones, because it often repeats one of them. A fit is compiled when all its inputs are such equations, and it names them; one measured point makes it experimental. Where both exist, the record's checks compare RefData with the compilation as a fraction (the vapour pressure only where RefData's is at least 1 kPa), except the enthalpy and Gibbs energy of formation, compared as a difference in kJ/mol.
- derived: computed from other RefData values, for example the acentric factor from the vapour pressure at 0.7 Tc, or the critical compressibility from Tc, Pc and Vc.
- predicted: a Cheméo prediction, used when nothing else exists.
A fit also gives the number of points it used and its average absolute relative deviation (AARD) from them. An equation adopted as published, such as a Joback heat capacity, has no AARD.
What an AARD measures depends on the basis. For an experimental fit it is the agreement with Cheméo's measurements. For a compiled fit, the inputs are points sampled from published equations (ChemSep's, KDB's, for example), so a small AARD, even 0.0%, says that RefData reproduces those equations, not that it matches measurements. The record's checks compare RefData with the compilations (ChemSep, ChEDL) where both exist.
Binary interaction parameters
RefData gives one constant kij per pair of compounds and per model, PR or SRK, fitted with the RefData parameters of the same version on Cheméo's mixture vapour-liquid equilibrium data. A kij is valid only with those parameters. Each one gives the points it was fitted on, their temperature and pressure ranges, and its average absolute relative deviation on pressure (AARD), with and without the kij. The grade is A when the AARD is 5% or less and B when it is 15% or less; a grade B kij describes the system poorly, and an activity model is the better choice. A grade says nothing outside the fitted range, nor about a pair that splits into two liquids.
The vapour pressure
RefData fits the DIPPR 101 equation in reduced temperature, anchored at the critical point and, when it is measured, at the normal boiling point. Fitted correlations among the inputs (Yaws' Antoine equations, KDB, the NIST WebBook Antoine equations) are dropped one by one, the worst first, while they deviate from the fitted curve by more than 3% in the median; measured points are never dropped this way. Among the exponents E = 1, 2 and 6 of the equation, RefData takes the one that fits the data best among those whose Peng-Robinson and SRK parameters reproduce the curve within 1%. A compound whose curve misses its own inputs by more than 10% on average is not published.
The equation of state and the interaction parameters
The PR and SRK blocks are fitted to the RefData vapour pressure, so a simulator that uses them reproduces it. Each block gives Tc, Pc, ω, the alpha coefficients c1, c2, c3 and a volume shift, used as follows, with T in K, P in Pa and R = 8.314462618 J/(mol·K):
-
Attraction and covolume: a(T) = Ωa·R²·Tc²/Pc·α(T) and b = Ωb·R·Tc/Pc, with Ωa = 0.45724 and Ωb = 0.07780 for PR, Ωa = 0.42748 and Ωb = 0.08664 for SRK.
-
Mathias-Copeman alpha function, with Tr = T/Tc:
- α(T) = [1 + c1·(1 − √Tr) + c2·(1 − √Tr)² + c3·(1 − √Tr)³]² for T ≤ Tc;
- α(T) = [1 + c1·(1 − √Tr)]² above Tc.
The coefficients are fitted so that the equation's own vapour pressure matches RefData's between 0.45·Tc (or the curve's lowest temperature) and 0.95·Tc.
-
Péneloux volume shift: v = v_EOS − vt, in m³/kmol, chosen so that the liquid volume at 0.7·Tc matches RefData's liquid density there; 0 when the compound has no liquid density. The shift changes volumes and densities, not the phase equilibrium. Binary interaction parameters (kij) are fitted with exactly these blocks. A kij is valid only with the EOS blocks of the same RefData version: used with another databank's critical constants, it describes a different model.
A worked evaluation
Hexane's vapour pressure is a dippr-101:
Y = exp(A + B/T + C·ln(T) + D·T^E), with Y in kPa and T in K
| Coefficient | Value |
|---|---|
| A | 79.71580147910379 |
| B | -6360.712436983037 |
| C | -9.856177450989067 |
| D | 8.667766191364632e-06 |
| E | 2 |
At T = 341.9 K, inside its range of 177.70 to 507.65 K, it gives 101.388885555252 kPa, one atmosphere within a tenth of a percent: 341.9 K is hexane's normal boiling point.
Using the data
Each record can be downloaded as JSON from its page, and the JSON Schema describes the format, so that a simulator can import it. The same records are available through the API and the MCP server.