Physical Properties
Property
Value
Unit
Source
ω
0.2753
Relay (1.0) Calculated Property
Δc H°liquid
-3120.00 ± 2.00
kJ/mol
NIST
Δf G°
218.66
kJ/mol
Joback Calculated Property
Δf H°gas
252.00 ± 5.90
kJ/mol
NIST
Δf H°liquid
187.00 ± 4.20
kJ/mol
NIST
Δfus H°
13.76
kJ/mol
Joback Calculated Property
Δvap H°
64.90 ± 4.20
kJ/mol
NIST
IE
8.56
eV
Relay (1.0) Calculated Property
log 10 WS
-4.43
Relay (1.0) Calculated Property
log Poct/wat
2.896
Crippen Calculated Property
McVol
123.280
ml/mol
McGowan Calculated Property
Pc
4316.89
kPa
Joback Calculated Property
Inp
[1445.00; 1445.00]
Inp
1445.00
NIST
Inp
1445.00
NIST
Inp
1445.00
NIST
I
[2244.00; 2244.00]
I
2244.00
NIST
I
2244.00
NIST
Tboil
536.04
K
Relay (1.0) Calculated Property
Tc
789.74
K
Relay (1.0) Calculated Property
Tfus
[296.55; 300.00]
K
Tfus
297.00 ± 1.50
K
NIST
Tfus
300.00 ± 1.50
K
NIST
Tfus
296.55 ± 0.50
K
NIST
Tfus
296.55 ± 0.50
K
NIST
Vc
0.404
m3 /kmol
Relay (1.0) Calculated Property
Temperature Dependent Properties
Property
Value
Unit
Temperature (K)
Source
Cp,gas
[177.84; 213.82]
J/mol×K
[554.82; 852.59]
Cp,gas
177.84
J/mol×K
554.82
Joback Calculated Property
Cp,gas
185.64
J/mol×K
604.45
Joback Calculated Property
Cp,gas
192.58
J/mol×K
654.08
Joback Calculated Property
Cp,gas
198.77
J/mol×K
703.70
Joback Calculated Property
Cp,gas
204.30
J/mol×K
753.33
Joback Calculated Property
Cp,gas
209.28
J/mol×K
802.96
Joback Calculated Property
Cp,gas
213.82
J/mol×K
852.59
Joback Calculated Property
Cp,liquid
[190.00; 194.00]
J/mol×K
[298.15; 330.00]
Cp,liquid
190.00
J/mol×K
298.15
NIST
Cp,liquid
190.00
J/mol×K
300.00
Zabransky, M., Ruzicka, V., Majer, V. and Domalski, E. (1997), Heat Capacity of Liquids: Critical Review and Recommended Values - Monograph No. 6, J. Phys. & Chem. Ref. Data (JPCRD), National Institute of Standards and Technology, Gaithersburg, MD
Cp,liquid
191.00
J/mol×K
310.00
Zabransky, M., Ruzicka, V., Majer, V. and Domalski, E. (1997), Heat Capacity of Liquids: Critical Review and Recommended Values - Monograph No. 6, J. Phys. & Chem. Ref. Data (JPCRD), National Institute of Standards and Technology, Gaithersburg, MD
Cp,liquid
193.00
J/mol×K
320.00
Zabransky, M., Ruzicka, V., Majer, V. and Domalski, E. (1997), Heat Capacity of Liquids: Critical Review and Recommended Values - Monograph No. 6, J. Phys. & Chem. Ref. Data (JPCRD), National Institute of Standards and Technology, Gaithersburg, MD
Cp,liquid
194.00
J/mol×K
330.00
Zabransky, M., Ruzicka, V., Majer, V. and Domalski, E. (1997), Heat Capacity of Liquids: Critical Review and Recommended Values - Monograph No. 6, J. Phys. & Chem. Ref. Data (JPCRD), National Institute of Standards and Technology, Gaithersburg, MD
η
[0.0003327; 0.0029814]
Pa×s
[312.44; 554.82]
η
0.0029814
Pa×s
312.44
Joback Calculated Property
η
0.0016781
Pa×s
352.84
Joback Calculated Property
η
0.0010629
Pa×s
393.23
Joback Calculated Property
η
0.0007331
Pa×s
433.63
Joback Calculated Property
η
0.0005386
Pa×s
474.03
Joback Calculated Property
η
0.0004154
Pa×s
514.42
Joback Calculated Property
η
0.0003327
Pa×s
554.82
Joback Calculated Property
Δfus H
[14.01; 14.08]
kJ/mol
[296.55; 296.60]
Δfus H
14.08
kJ/mol
296.55
NIST
Δfus H
14.08
kJ/mol
296.55
NIST
Δfus H
14.01
kJ/mol
296.60
NIST
Δfus H
14.01
kJ/mol
296.60
NIST
Δfus S
[47.50; 47.50]
J/mol×K
[296.55; 296.55]
Δfus S
47.50
J/mol×K
296.55
NIST
Δfus S
47.50
J/mol×K
296.55
NIST
Pressure Dependent Properties
Property
Value
Unit
Pressure (kPa)
Source
Tboilr
425.20
K
2.00
NIST
Correlations
Property
Value
Unit
Temperature (K)
Source
Pvap
[1.33; 202.65]
kPa
[425.12; 619.67]
The Yaws Handbook of Vapor Pressure
Equation ln(Pvp) = A + B/(T + C) Coefficient A 1.37879e+01 Coefficient B -4.43145e+03 Coefficient C -9.68720e+01 Temperature range, min. 425.12
Temperature range, max. 619.67
Pvap
1.33
kPa
425.12
Calculated Property
Pvap
3.07
kPa
446.74
Calculated Property
Pvap
6.42
kPa
468.35
Calculated Property
Pvap
12.36
kPa
489.97
Calculated Property
Pvap
22.25
kPa
511.59
Calculated Property
Pvap
37.78
kPa
533.20
Calculated Property
Pvap
61.02
kPa
554.82
Calculated Property
Pvap
94.38
kPa
576.44
Calculated Property
Pvap
140.60
kPa
598.05
Calculated Property
Pvap
202.65
kPa
619.67
Calculated Property
Similar Compounds
Find more compounds similar to Benzene, 1,2-diiodo- .
Sources
Cheméo Relay (1.0)
Crippen Method
Crippen Method
Joback Method
McGowan Method
NIST Webbook
The Yaws Handbook of Vapor Pressure
Zabransky, M., Ruzicka, V., Majer, V. and Domalski, E. (1997), Heat Capacity of Liquids: Critical Review and Recommended Values - Monograph No. 6, J. Phys. & Chem. Ref. Data (JPCRD), National Institute of Standards and Technology, Gaithersburg, MD
Note: Cheméo is only indexing the data, follow the source links to retrieve the latest data. The source is also providing more information like the publication year, authors and more.
Take the time to validate and double check the source of the data.
These property values are available through the Cheméo API . A free account gives you an access key.