Physical Properties
Property
Value
Unit
Source
ω
1.1885
Relay (1.0) Calculated Property
Δc H°liquid
[-20503.30; -20492.00]
kJ/mol
Δc H°liquid
-20503.30 ± 8.40
kJ/mol
NIST
Δc H°liquid
-20492.00 ± 7.90
kJ/mol
NIST
Δf G°
207.70
kJ/mol
Joback Calculated Property
Δf H°gas
[-711.20; -700.00]
kJ/mol
Δf H°gas
-700.00 ± 9.20
kJ/mol
NIST
Δf H°gas
-711.20
kJ/mol
NIST
Δf H°liquid
[-853.40; -842.20]
kJ/mol
Δf H°liquid
-842.20 ± 8.80
kJ/mol
NIST
Δf H°liquid
-853.40 ± 8.00
kJ/mol
NIST
Δfus H°
72.52
kJ/mol
Joback Calculated Property
Δvap H°
[142.00; 142.00]
kJ/mol
Δvap H°
142.00 ± 0.80
kJ/mol
NIST
Δvap H°
142.00 ± 0.80
kJ/mol
NIST
IE
9.95
eV
Relay (1.0) Calculated Property
log 10 WS
-11.53
Relay (1.0) Calculated Property
log Poct/wat
12.195
Crippen Calculated Property
McVol
447.650
ml/mol
McGowan Calculated Property
Pc
570.69
kPa
Joback Calculated Property
S°liquid
1086.20
J/mol×K
NIST
Tboil
648.46
K
Relay (1.0) Calculated Property
Tc
815.84
K
Relay (1.0) Calculated Property
Tfus
[281.85; 283.20]
K
Tfus
Outlier 283.20 ± 2.00
K
NIST
Tfus
282.20 ± 1.00
K
NIST
Tfus
281.85 ± 0.40
K
NIST
Tfus
281.90 ± 0.50
K
NIST
Tfus
282.40 ± 1.00
K
NIST
Tfus
281.85 ± 0.40
K
NIST
Ttriple
[282.34; 282.34]
K
Ttriple
282.34 ± 0.10
K
NIST
Ttriple
282.34 ± 0.10
K
NIST
Vc
1.743
m3 /kmol
Relay (1.0) Calculated Property
Temperature Dependent Properties
Property
Value
Unit
Temperature (K)
Source
Cp,gas
[1550.16; 1695.88]
J/mol×K
[908.24; 1122.22]
Cp,gas
1550.16
J/mol×K
908.24
Joback Calculated Property
Cp,gas
1578.28
J/mol×K
943.90
Joback Calculated Property
Cp,gas
1604.74
J/mol×K
979.57
Joback Calculated Property
Cp,gas
1629.63
J/mol×K
1015.23
Joback Calculated Property
Cp,gas
1653.05
J/mol×K
1050.89
Joback Calculated Property
Cp,gas
1675.10
J/mol×K
1086.56
Joback Calculated Property
Cp,gas
1695.88
J/mol×K
1122.22
Joback Calculated Property
Cp,liquid
[937.60; 950.80]
J/mol×K
[290.00; 300.00]
Cp,liquid
937.60
J/mol×K
290.00
Zabransky, M., Ruzicka, V., Majer, V. and Domalski, E. (1997), Heat Capacity of Liquids: Critical Review and Recommended Values - Monograph No. 6, J. Phys. & Chem. Ref. Data (JPCRD), National Institute of Standards and Technology, Gaithersburg, MD
Cp,liquid
944.20
J/mol×K
295.00
Zabransky, M., Ruzicka, V., Majer, V. and Domalski, E. (1997), Heat Capacity of Liquids: Critical Review and Recommended Values - Monograph No. 6, J. Phys. & Chem. Ref. Data (JPCRD), National Institute of Standards and Technology, Gaithersburg, MD
Cp,liquid
948.40
J/mol×K
298.15
Zabransky, M., Ruzicka, V., Majer, V. and Domalski, E. (1997), Heat Capacity of Liquids: Critical Review and Recommended Values - Monograph No. 6, J. Phys. & Chem. Ref. Data (JPCRD), National Institute of Standards and Technology, Gaithersburg, MD
Cp,liquid
950.80
J/mol×K
300.00
Zabransky, M., Ruzicka, V., Majer, V. and Domalski, E. (1997), Heat Capacity of Liquids: Critical Review and Recommended Values - Monograph No. 6, J. Phys. & Chem. Ref. Data (JPCRD), National Institute of Standards and Technology, Gaithersburg, MD
Cp,liquid
949.80
J/mol×K
300.00
NIST
η
[0.0000191; 0.0011568]
Pa×s
[424.13; 908.24]
η
0.0011568
Pa×s
424.13
Joback Calculated Property
η
0.0003377
Pa×s
504.81
Joback Calculated Property
η
0.0001384
Pa×s
585.50
Joback Calculated Property
η
0.0000704
Pa×s
666.18
Joback Calculated Property
η
0.0000415
Pa×s
746.87
Joback Calculated Property
η
0.0000271
Pa×s
827.56
Joback Calculated Property
η
0.0000191
Pa×s
908.24
Joback Calculated Property
Δfus H
[71.13; 71.21]
kJ/mol
[282.30; 282.34]
Δfus H
71.13
kJ/mol
282.30
NIST
Δfus H
71.13
kJ/mol
282.30
NIST
Δfus H
71.21
kJ/mol
282.34
NIST
Δfus H
71.21
kJ/mol
282.34
NIST
Δvap H
110.90
kJ/mol
305.50
NIST
Δfus S
[252.20; 252.20]
J/mol×K
[282.34; 282.34]
Δfus S
252.20
J/mol×K
282.34
NIST
Δfus S
252.20
J/mol×K
282.34
NIST
Correlations
Property
Value
Unit
Temperature (K)
Source
Pvap
[1.33; 202.66]
kPa
[564.92; 757.16]
The Yaws Handbook of Vapor Pressure
Equation ln(Pvp) = A + B/(T + C) Coefficient A 1.63010e+01 Coefficient B -6.73381e+03 Coefficient C -1.44410e+02 Temperature range, min. 564.92
Temperature range, max. 757.16
Pvap
1.33
kPa
564.92
Calculated Property
Pvap
2.89
kPa
586.28
Calculated Property
Pvap
5.84
kPa
607.64
Calculated Property
Pvap
11.08
kPa
629.00
Calculated Property
Pvap
19.92
kPa
650.36
Calculated Property
Pvap
34.15
kPa
671.72
Calculated Property
Pvap
56.15
kPa
693.08
Calculated Property
Pvap
88.94
kPa
714.44
Calculated Property
Pvap
136.27
kPa
735.80
Calculated Property
Pvap
202.66
kPa
757.16
Calculated Property
Similar Compounds
Find more compounds similar to Heneicosane, 11-decyl- .
Sources
Cheméo Relay (1.0)
Crippen Method
Crippen Method
Joback Method
McGowan Method
NIST Webbook
The Yaws Handbook of Vapor Pressure
Zabransky, M., Ruzicka, V., Majer, V. and Domalski, E. (1997), Heat Capacity of Liquids: Critical Review and Recommended Values - Monograph No. 6, J. Phys. & Chem. Ref. Data (JPCRD), National Institute of Standards and Technology, Gaithersburg, MD
Note: Cheméo is only indexing the data, follow the source links to retrieve the latest data. The source is also providing more information like the publication year, authors and more.
Take the time to validate and double check the source of the data.
Outlier This icon means
that the value is more than 2 standard deviations away from the
property mean.
These property values are available through the Cheméo API . A free account gives you an access key.