Chemical Properties of Succinic acid, 2,3,4,6-tetrachlorophenyl tridecyl ester

Succinic acid, 2,3,4,6-tetrachlorophenyl tridecyl ester

InChI
InChI=1S/C23H32Cl4O4/c1-2-3-4-5-6-7-8-9-10-11-12-15-30-19(28)13-14-20(29)31-23-18(25)16-17(24)21(26)22(23)27/h16H,2-15H2,1H3
InChI Key
FFQOTIQTIMSPCZ-UHFFFAOYSA-N
Formula
C23H32Cl4O4
SMILES
CCCCCCCCCCCCCOC(=O)CCC(=O)Oc1c(Cl)cc(Cl)c(Cl)c1Cl
Molecular Weight1
514.31
Cheméo is a service of Céondo GmbH, since 2007, we provide simulation, modelling and software development services for the industry. Do not hesitate to contact us for your projects.

Physical Properties

Property Value Unit Source
ΔfH°gas -970.03 kJ/mol Relay (1.0) Calculated Property
ΔfusH° 73.34 kJ/mol Joback Calculated Property
ΔvapH° 134.91 kJ/mol Relay (1.0) Calculated Property
log10WS -8.81 Relay (1.0) Calculated Property
logPoct/wat 8.840 Crippen Calculated Property
McVol 375.010 ml/mol McGowan Calculated Property
Inp 3393.00 NIST
Tboil 678.79 K Relay (1.0) Calculated Property
Tc 943.93 K Relay (1.0) Calculated Property
Tfus 332.77 K Relay (1.0) Calculated Property

Cheméo can also estimate Critical Pressure, Critical Volume, Standard Gibbs free energy of formation, Acentric Factor, Ionization energy for this compound, but they fall outside the models' validated range, so they are not shown here. Open the prediction tool to compute them on demand.

Correlations

Property Value Unit Temperature (K) Source
Cp,gas [532.64; 1124.53] J/mol×K [273.00; 1000.00] Joback Predicted correlation Show Hide
EquationY = A + B·T + C·T² + D·T³ + E·T⁴
Y is Cp,gas in J/mol×K, T in K
Coefficient A1.07654e+02
Coefficient B1.78952e+00
Coefficient C-8.82840e-04
Coefficient D1.10200e-07
Coefficient E0.00000e+00
Temperature range, min.273.00
Temperature range, max.1000.00
Cp,gas 532.64 J/mol×K 273.00 Calculated Property
Cp,gas 635.13 J/mol×K 353.78 Calculated Property
Cp,gas 727.63 J/mol×K 434.56 Calculated Property
Cp,gas 810.48 J/mol×K 515.33 Calculated Property
Cp,gas 884.03 J/mol×K 596.11 Calculated Property
Cp,gas 948.64 J/mol×K 676.89 Calculated Property
Cp,gas 1004.64 J/mol×K 757.67 Calculated Property
Cp,gas 1052.39 J/mol×K 838.44 Calculated Property
Cp,gas 1092.24 J/mol×K 919.22 Calculated Property
Cp,gas 1124.53 J/mol×K 1000.00 Calculated Property
Property Value Unit Temperature (K) Source
η [0.0001493; 0.0000259] Pa×s [629.81; 890.29] Joback Predicted correlation Show Hide
EquationY = exp(A + B/T + C·ln(T) + D·T^E)
Y is η in Pa×s, T in K
Coefficient A-1.47942e+01
Coefficient B3.76922e+03
Coefficient C0.00000e+00
Coefficient D0.00000e+00
Coefficient E0.00000e+00
CommentLiquid phase. Joback/Reid (1987), valid from Tf to 0.7·Tc.
Temperature range, min.629.81
Temperature range, max.890.29
η 0.0001493 Pa×s 629.81 Calculated Property
η 0.0001148 Pa×s 658.75 Calculated Property
η 0.0000902 Pa×s 687.70 Calculated Property
η 0.0000723 Pa×s 716.64 Calculated Property
η 0.0000590 Pa×s 745.58 Calculated Property
η 0.0000488 Pa×s 774.52 Calculated Property
η 0.0000410 Pa×s 803.47 Calculated Property
η 0.0000348 Pa×s 832.41 Calculated Property
η 0.0000299 Pa×s 861.35 Calculated Property
η 0.0000259 Pa×s 890.29 Calculated Property

Similar Compounds

Succinic acid, heptyl 2,3,4,6-tetrachlorophenyl ester. Succinic acid, 2,3,4,6-tetrachlorophenyl undecyl ester. Succinic acid, octyl 2,3,4,6-tetrachlorophenyl ester. Succinic acid, dodecyl 2,3,4,6-tetrachlorophenyl ester. Succinic acid, decyl 2,3,4,6-tetrachlorophenyl ester. Succinic acid, nonyl 2,3,4,6-tetrachlorophenyl ester. Succinic acid, hexyl 2,3,4,6-tetrachlorophenyl ester. Succinic acid, pentyl 2,3,4,6-tetrachlorophenyl ester. Succinic acid, tetradecyl 2,3,6-trichlorophenyl ester. Succinic acid, 2,3,6-trichlorophenyl tridecyl ester. Succinic acid, 2,3,6-trichlorophenyl undecyl ester. Succinic acid, heptyl 2,3,6-trichlorophenyl ester. Succinic acid, nonyl 2,3,6-trichlorophenyl ester. Succinic acid, decyl 2,3,6-trichlorophenyl ester. Succinic acid, pentadecyl 2,3,6-trichlorophenyl ester.

Find more compounds similar to Succinic acid, 2,3,4,6-tetrachlorophenyl tridecyl ester.

Sources

Note: Cheméo is only indexing the data, follow the source links to retrieve the latest data. The source is also providing more information like the publication year, authors and more. Take the time to validate and double check the source of the data.
Calculated This icon marks a calculated value or equation: a prediction, not a measurement.
These property values are available through the Cheméo API. A free account gives you an access key.