Chemical Properties of Succinic acid, 2,2-dichloroethyl eicosyl ester

Succinic acid, 2,2-dichloroethyl eicosyl ester

InChI
InChI=1S/C26H48Cl2O4/c1-2-3-4-5-6-7-8-9-10-11-12-13-14-15-16-17-18-19-22-31-25(29)20-21-26(30)32-23-24(27)28/h24H,2-23H2,1H3
InChI Key
CSSVAYINGKRSTQ-UHFFFAOYSA-N
Formula
C26H48Cl2O4
SMILES
CCCCCCCCCCCCCCCCCCCCOC(=O)CCC(=O)OCC(Cl)Cl
Molecular Weight1
495.56
Cheméo is a service of Céondo GmbH, since 2007, we provide simulation, modelling and software development services for the industry. Do not hesitate to contact us for your projects.

Physical Properties

Property Value Unit Source
ΔfH°gas -1229.87 kJ/mol Relay (1.0) Calculated Property
ΔfusH° 76.70 kJ/mol Joback Calculated Property
ΔvapH° 137.83 kJ/mol Relay (1.0) Calculated Property
log10WS -8.45 Relay (1.0) Calculated Property
logPoct/wat 8.698 Crippen Calculated Property
McVol 416.560 ml/mol McGowan Calculated Property
Pc 703.59 kPa Joback Calculated Property
Inp [3329.00; 3329.00]   Show Hide
Inp 3329.00 NIST
Inp 3329.00 NIST
Tboil 675.26 K Relay (1.0) Calculated Property
Tc 865.98 K Relay (1.0) Calculated Property
Tfus 320.16 K Relay (1.0) Calculated Property

Cheméo can also estimate Critical Volume, Standard Gibbs free energy of formation, Acentric Factor, Ionization energy for this compound, but they fall outside the models' validated range, so they are not shown here. Open the prediction tool to compute them on demand.

Correlations

Property Value Unit Temperature (K) Source
Cp,gas [616.21; 1393.99] J/mol×K [273.00; 1000.00] Joback Predicted correlation Show Hide
EquationY = A + B·T + C·T² + D·T³ + E·T⁴
Y is Cp,gas in J/mol×K, T in K
Coefficient A5.41720e+01
Coefficient B2.38372e+00
Coefficient C-1.24540e-03
Coefficient D2.01500e-07
Coefficient E0.00000e+00
Temperature range, min.273.00
Temperature range, max.1000.00
Cp,gas 616.21 J/mol×K 273.00 Calculated Property
Cp,gas 750.53 J/mol×K 353.78 Calculated Property
Cp,gas 871.39 J/mol×K 434.56 Calculated Property
Cp,gas 979.42 J/mol×K 515.33 Calculated Property
Cp,gas 1075.27 J/mol×K 596.11 Calculated Property
Cp,gas 1159.56 J/mol×K 676.89 Calculated Property
Cp,gas 1232.95 J/mol×K 757.67 Calculated Property
Cp,gas 1296.05 J/mol×K 838.44 Calculated Property
Cp,gas 1349.52 J/mol×K 919.22 Calculated Property
Cp,gas 1393.99 J/mol×K 1000.00 Calculated Property
Property Value Unit Temperature (K) Source
η [0.0004028; 0.0000192] Pa×s [512.28; 851.27] Joback Predicted correlation Show Hide
EquationY = exp(A + B/T + C·ln(T) + D·T^E)
Y is η in Pa×s, T in K
Coefficient A-1.54663e+01
Coefficient B3.91850e+03
Coefficient C0.00000e+00
Coefficient D0.00000e+00
Coefficient E0.00000e+00
CommentLiquid phase. Joback/Reid (1987), valid from Tf to 0.7·Tc.
Temperature range, min.512.28
Temperature range, max.851.27
η 0.0004028 Pa×s 512.28 Calculated Property
η 0.0002385 Pa×s 549.95 Calculated Property
η 0.0001511 Pa×s 587.61 Calculated Property
η 0.0001011 Pa×s 625.28 Calculated Property
η 0.0000708 Pa×s 662.94 Calculated Property
η 0.0000515 Pa×s 700.61 Calculated Property
η 0.0000387 Pa×s 738.27 Calculated Property
η 0.0000299 Pa×s 775.94 Calculated Property
η 0.0000237 Pa×s 813.61 Calculated Property
η 0.0000192 Pa×s 851.27 Calculated Property

Similar Compounds

Succinic acid, 2,2-dichloroethyl tridecyl ester. Succinic acid, 2,2-dichloroethyl heptadecyl ester. Succinic acid, 2,2-dichloroethyl undecyl ester. Succinic acid, 2,2-dichloroethyl pentadecyl ester. Succinic acid, 2,2-dichloroethyl hexadecyl ester. Succinic acid, 2,2-dichloroethyl tetradecyl ester. Succinic acid, decyl 2,2-dichloroethyl ester. Succinic acid, 2,2-dichloroethyl dodecyl ester. Succinic acid, 2,2-dichloroethyl octyl ester. Succinic acid, 2,2-dichloroethyl nonyl ester. Succinic acid, 2,2-dichloroethyl heptyl ester. Succinic acid, 2,2-dichloroethyl octadecyl ester. Succinic acid, 2,2-dichloroethyl nonadecyl ester. Succinic acid, 2,2-dichloroethyl hexyl ester. Succinic acid, nonyl 2,2,2-trichloroethyl ester.

Find more compounds similar to Succinic acid, 2,2-dichloroethyl eicosyl ester.

Sources

Note: Cheméo is only indexing the data, follow the source links to retrieve the latest data. The source is also providing more information like the publication year, authors and more. Take the time to validate and double check the source of the data.
Calculated This icon marks a calculated value or equation: a prediction, not a measurement.
These property values are available through the Cheméo API. A free account gives you an access key.